Skip to content
  • Brazil
  • Canada
  • Europe
  • India
  • Italy
  • Japan
  • Korea
  • Latam
  • Spain
  • Taiwan
  • The Middle East
  • Turkey
  • United Kingdom
  • United States
  • 語言
  • 02-2697-1737 聯繫我們
  • 02-2697-1737 聯繫我們
TaiwanTaiwan
  • Part of brands: |
  • 最新消息
    • 台灣艾捷隆最新消息
    • 勇氣媽咪 – Podcast
    • 好孕部落格
  • 好孕啟程
    • 懷孕前
    • 生殖療程選項
    • 健康懷孕
    • 出生後
  • 好孕衛教專欄
    • 好孕知識分享
    • ERA知識分享
    • EMMA,ALICE知識分享
    • 求子故事 – 真摯分享
    • 論文專區
  • 我是生殖醫學專家
    • ERA®子宮內膜容受性檢測
    • EMMA 子宮內膜菌叢檢測
    • ALICE 感染性慢性子宮內膜炎檢測
    • EndomeTRIO 子宮內膜三合一檢測
    • CGT 特定基因帶有者檢測
    • PGT-A 胚胎著床前染色體篩檢
    • PGT-M 單一基因遺傳性疾病檢測
    • PGT-SR 結構重排的植入前基因檢測
    • POC 流產物質染色體篩檢
    • SAT 精子染色體異常檢測
  • Academy
Smart PGT-A Plus

Smart PGT-A Plus

Our most advanced 4-in-1 genetic test offers increased accuracy and confidence for embryo transfer.

Combines two in-house validated technologies (NGS + SNPs analysis) 

Superior accuracy and enhanced confidence to detect any abnormalities

Increases the number of viable embryos available for transfer

想了解更多!

請索取更多檢測資訊
或 email 至: servicetaiwan@igenomix.com
Overview
  • To enhance the genetic testing of IVF embryos and expand the diagnostic capabilities and clinical utility of our preimplantation genetic testing for aneuploidy (Smart PGT-A), we have developed and validated a parallel targeted Next-Generation Sequencing (NGS) strategy using the power of SNP technology with out the need for parental samples.
  • Single Nucleotide Polymorphisms (SNPs) are changes in single nucleotides distributed throughout the genome and frequently vary at the same genomic position between individuals. Most SNPs have only two different alleles.
  • SNPs can be used for ‘DNA fingerprinting’ to detect ploidy differences, DNA contamination and the genetic relatedness of embryos.
  • This dual assessment serves as a complementary test for the detection of the chromosome abnormalities not detected with our current approach, significantly enhancing the accuracy and confidence of the Smart PGT-A test.

What is Smart PGT-A Plus?

  • Building upon our expertise, our latest offering, Smart PGT-A Plus, is a 4-in-1 genetic test which combines our extensively validated in-house Next Generation Sequencing (NGS) technology with an additional and validated targeted Next Generation Sequencing (NGS) strategy using the power of SNPs (Single Nucleotide Polymorphism) without the need for parental samples.
  • This advanced screening solution goes beyond Smart PGT-A by incorporating additional features including ploidy analysis (complete chromosomes sets), sibling embryo genetic relatedness and DNA contamination detection into a standard PGT-A workflow significantly increasing accuracy and confidence in selecting the optimal embryo for transfer.

Smart PGT-A Plus

Our most advanced 4-in-1 genetic test solution

Smart PGT- A

Our custom and validated technology that combines next-generation sequencing (NGS) with advanced algorithms and machine learning, enabling the analysis of genomic data from embryos with exceptional accuracy and reliability.

Genetic PN Check | Ploidy detection

Smart PGT-A Plus enables the detection of both haploidy and triploidy. This crucial assessment ensures the selection of embryos with the correct chromosomal content, minimizing the risk of genetic abnormalities. Smart PGT-A Plus also increases the number of viable euploid embryos available for transfer by detecting true 2PN (diploid) embryos from among morphologically identified 0, 1 and 2.1/3PN embryos.

Siblings QC | DNA Fingerrintingiblings

Our quality control process includes Siblings QC, where we employ DNA fingerprinting techniques. This ensures accurate identification, differentiation and the assurance that the tested embryo is genetically related to the others in the patient’s cohort reducing the risk of sample mix-ups due to human error.

Detection of DNA Contamination

We have implemented measures to identify and detect both external cell/DNA and maternal cell contamination increasing the accuracy and confidence of the testing process significantly reducing the risk of misdiagnosis.

Smart PGT-A & Smart PGT-A Plus Compared

What is the procedure?

Smart PGT-A Plus uses two independent analysis on every sample to deliver a comprehensive 4-in-1 genetic test for aneuploidy in embryos.

Features
  • Benefits
  • Indications
  • Test Limitations

What makes our Smart PGT-A Plus stand out from the rest?

Offers enhanced confidence with robust and accurate results, utilizing two independent analyses to detect abnormalities.

Increases the number of viable embryos available for transfer.

Strengthened by the power of big data and artificial intelligence, effectively overcoming the limitations of human subjectivity and greatly reducing the risk of human error.

Enhances accuracy and reduces the risk of misdiagnosis by detecting external and maternal cell DNA contamination.

Maximizes the likelihood of successful pregnancy by carefully identifying optimal embryos for transfer.

Provides confirmation that all embryos from the same patient are genetically related to each other without the need for additional parental samples.

Reduces the risk of miscarriage due to previously undetected abnormalities (e.g. triploidy).

Ensures enhanced quality control in the laboratory procedures conducted within your IVF lab, providing greater assurance.

While any couple can have an embryo with aneuploidy, the chances can increase with the following factors:

  • Female age over 35

  • History of recurrent pregnancy loss

  • Previous IVF failure

  • Prior child or pregnancy with a chromosome abnormality

  • Rescue embryos following abnormal fertilization (0PN, 1PN, 2.1PN/3PN)

  • Reproductive history of triploidy/haploidy

  • Complete or partial molar pregnancy

  • Recurrent miscarriage

  • Sibling relatedness analysis can only be performed for cohorts of 2 or more diploid embryos. Cannot be reported for chaotic, haploid or triploid embryos, or when ploidy analysis is non-informative.
  • The origin of contamination cannot be determined when an admixture of contamination is detected.
  • The origin of the sample cannot be determined when a sibling mismatch is detected. Possibilities include:
    • Complete exogenous contamination.
    • DNA from an unexpected embryo.
    • Biological diversity.
  • Smart PGT-A Plus cannot confirm that the correct embryo was transferred.

若您對技術性資料感到困惑…

我們能如何協助您?

我是備孕爸媽

遺傳解決方案

Igenomix 提供創新的檢測以幫助生殖醫學專家解決患者的生殖問題。在患者生殖歷程的懷孕前、植入前與生產前的各階段,為患者提供全面的高品質解決方案。

了解更多有關 Igenomix 的訊息

Igenomix 媒體報導

WE GUIDE YOU

生殖醫學
遺傳疾病預防
健康懷孕

OUR SERVICE

基因檢測方案
使用者手冊

ABOUT US

品質相關
加入我們

Follow US

台灣艾捷隆股份有限公司 221416 新北市汐止區新台五路一段99號30樓之11

營業時間:周一至周五 上午 9 點至下午 6 點

聯繫我們:servicetaiwan@igenomix.com

02-2697-1737 聯繫我們

[2024] © Igenomix 隱私權政策 品質政策 法務聲明 Cookies policy

Open this in UX Builder to add and edit content

  • 最新消息
    • 台灣艾捷隆最新消息
    • 勇氣媽咪 – Podcast
    • 好孕部落格
  • 好孕啟程
    • 懷孕前
    • 生殖療程選項
    • 健康懷孕
    • 出生後
  • 好孕衛教專欄
    • 好孕知識分享
    • ERA知識分享
    • EMMA,ALICE知識分享
    • 求子故事 – 真摯分享
    • 論文專區
  • 我是生殖醫學專家
    • ERA®子宮內膜容受性檢測
    • EMMA 子宮內膜菌叢檢測
    • ALICE 感染性慢性子宮內膜炎檢測
    • EndomeTRIO 子宮內膜三合一檢測
    • CGT 特定基因帶有者檢測
    • PGT-A 胚胎著床前染色體篩檢
    • PGT-M 單一基因遺傳性疾病檢測
    • PGT-SR 結構重排的植入前基因檢測
    • POC 流產物質染色體篩檢
    • SAT 精子染色體異常檢測
  • Academy
  • 語言